Invited: Searching for Majorana neutrinos with nEXO, Andrea Pocar

24 mai 2022, 15:30
30m
Main auditorium

Main auditorium

Physics Department Faculty of Science and Technology University of Coimbra Rua Larga, 3004-516 COIMBRA

Orateurs

Dr Andrea Pocar (University of Massachusetts, Amherst)Dr Thomas Brunner (McGill University and TRIUMF) Julien Masbou (SUBATECH)

Description

nEXO will search for neutrinoless double beta (0νββ) decay in 5 tonnes of xenon enriched to 90% in the ββ-decaying isotope xenon-136 [1]. The observation of 0νββ decay would imply lepton number non-conservation of an otherwise conserved quantity in nature. At the same time, it would require neutrinos and anti-neutrinos to be the same particle, i.e., a Majorana fermion, a unique property among fundamental particles of the Standard Model. The observation of 0νββ decay could occur via different underlying microphysics. A unique mass mechanism exists for Majorana particles that could explain why neutrinos are so light and link the neutrino mass with the 0νββ decay rate.

nEXO operates with 5 tonnes of liquid xenon (LXe) in single-phase in a cylindrical time-projection chamber (TPC) with diameter and height of about 1.3m [1]. The nEXO TPC measures the energy, position, and topological multiplicity of each event. By the simultaneous event-by-event detection of ionization and scintillation nEXO will have an anticipated energy resolution of better than 1% at the ββ endpoint with a projected 0νββ decay half-life sensitivity of 1.35 x 10$^{28}$ years (90%CL) after 10 years of lifetime [2].

The ionization electrons are recorded by a segmented anode plane at one end of the TPC [3]. The prompt VUV scintillation photons (175 nm) are recorded by a ~4.5m$^2$ array of VUV-sensitive silicon photomultipliers (SiPMs) mounted on the cylinder barrel surface [4]. Both detection systems will be immersed in the LXe, along with the front-end readout electronics. An extensive nEXO R&D program has focused on two SiPM options: VUV4 Multi-Pixel Photon Counter (MPPC) from Hamamatsu Photonics Inc. (HPK) and VUV-HD SiPM from Fondazione Bruno Kessler (FBK). Both devices meet nEXO’s requirements. Integration of SiPMs into larger modules is currently being detailed.

The status of nEXO’s photodetector and charge readout system will be presented along with measured performance parameters and a general overview of the nEXO technology.

References
[1] nEXO Collaboration (S. Al Kharusi, et al.), arXiv:1805.11142v2 (2018)
[2] nEXO Collaboration (G Adhikari et al.), J. Phys. G: Nucl. Part. Phys. 49, 015104 (2022).
[3] nEXO Collaboration (Z. Li, et al.), JINST 14, P09020 (2019)
[4] nEXO Collaboration (G. Gallina, et al.), NIMA 940, 371 (2019)

Auteurs principaux

Dr Andrea Pocar (University of Massachusetts, Amherst) Dr Thomas Brunner (McGill University and TRIUMF) nEXO collaboration Julien Masbou (SUBATECH)

Documents de présentation