12 novembre 2026
Granada Conference & Exhibition Centre
Fuseau horaire Europe/Madrid

Liste des Contributions

9 sur 9 affichés
Exporter en PDF
  1. Dr Olga KOCHEBINA
    12/11/2026 13:15

    OpenGATE collabriation news

    Aller à la page de la contribution
  2. Dr Jin Jegal (Korea Institute of Radiological and Medical Sciences, Department of Radiation Oncology, Seoul, Republic of Korea)
    12/11/2026 13:27

    Mesh-type Reference Computational Phantoms (MRCP) provide anatomically realistic tetrahedral organ structures, but their practical use in OpenGATE-based imaging and dosimetry simulations remains limited. In our previous work, a simplified tetrahedral phantom was imported using a tessellated solid-based workflow and evaluated with heart and body geometries. In this study, we extended the...

    Aller à la page de la contribution
  3. Elnaz Olyaei (Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, University of Tuebingen, Tuebingen, Germany)
    12/11/2026 13:39

    We are presenting the next steps of a simulation framework for a dedicated dual-layer, depthof-interaction (DOI)-capable breast PET insert integrated into the Siemens Biograph mMR
    PET/MR system. This work combines two complementary steps, the experimental calibration
    of the GATE detector model and the development of realistic, patient-derived breast phantoms,
    both aimed at enabling...

    Aller à la page de la contribution
  4. Stephan Naunheim (University of California, Davis)
    12/11/2026 13:51

    Prototyping novel scintillation detectors and PET/SPECT scanners heavily relies on Monte Carlo simulations to inform hardware optimization and data-processing development. While optical photon simulations remain the gold standard for detector modeling and provide details on spatial, energy, and TOF resolution, they are extremely time-consuming because they track thousands of optical photons...

    Aller à la page de la contribution
  5. Dr Matthew Strugari (Biomedical Imaging Research Group (GIBI230), Instituto de Investigación Sanitaria La Fe (IIS La Fe), Valencia, Spain)
    12/11/2026 14:03

    Purpose: Targeted alpha therapy (TAT) offers high biological effectiveness, but image-based treatment verification and dosimetry remain challenging due to complex radionuclide decay schemes and the highly localized energy deposition of alpha particles. Dose point kernels (DPKs) can support voxel-based dosimetry by describing the spatial distribution of energy deposition around a...

    Aller à la page de la contribution
  6. Marcin Balcerzyk (Bioaraba Health Research Institue)
    12/11/2026 14:15

    Background: Ultrafast Time-of-Flight (TOF) information in Gate 10 simulations enables direct 3D PET reconstruction without scanner-specific modeling. Although such picosecond timing is not achievable in current detectors, simulated data allow exploration of idealized TOF regimes and rapid evaluation of prototype PET designs. Methods: The TOF-driven reconstruction assigns each...

    Aller à la page de la contribution
  7. Theodoros Leontiou
    12/11/2026 14:27
  8. David Sarrut (CNRS)
    12/11/2026 14:39
  9. Olga KOCHEBINA