Indisponibilité programmée / Scheduled outage

Nous procéderons à une opération de maintenance le mercredi 12 mars 2025 à 8h00 (CET).

  • Indico sera indisponible durant cette opération.
  • La durée prévisionnelle d'indisponibilité est estimée à une heure.

We will be performing maintenance on Wednesday, March 12, 2025, at 8:00 AM (CET).

  • Indico will be unavailable during this operation.
  • The estimated downtime is one hour.
17 juin 2024
Laboratoire APC, Bâtiment Condorcet, 10 rue Alice Domon et Léonie Duquet, 75013, Paris
Fuseau horaire Europe/Paris

Study of the optical losses as a function of beam position on the mirrors in a 285 m suspended Fabry-Perot cavity

17 juin 2024, 14:40
20m
Amphithéâtre Pierre-Gilles de Gennes ( Laboratoire APC, Bâtiment Condorcet, 10 rue Alice Domon et Léonie Duquet, 75013, Paris)

Amphithéâtre Pierre-Gilles de Gennes

Laboratoire APC, Bâtiment Condorcet, 10 rue Alice Domon et Léonie Duquet, 75013, Paris

Orateur

M. Yuhang Zhao (APC, Université Paris Cité)

Description

Optical losses introduce noise, impair noise reduction techniques, and degrade signal gain in gravitational wave detectors. The squeezed vacuum state of light is a well-established method for quantum noise reduction. An optical cavity, often called a filter cavity, is essential to impose a frequency-dependent phase rotation on the squeezed vacuum. In the Virgo gravitational wave detector, the filter cavity is 284.9 meters long with a finesse of about 10,000.

In this talk, we report on the characterization of optical losses within the Virgo filter cavity. By using cavity angle information, we reconstructed the beam position inside the cavity and conducted an in-situ optical loss mapping. Our findings indicate that optical losses depend significantly on the beam's position on the input mirror, while losses are more uniform on the end mirror. The lowest measured losses are comparable to those expected from pre-installation mirror characterizations. The larger discrepancies observed for certain beam positions are likely due to contamination. Additionally, this methodology enabled the regulated identification of an optimal cavity axis position within half an hour, achieving some of the lowest round trip losses ever recorded. This work contributes to meeting the stringent loss requirements for the optical cavities of future gravitational wave detectors, such as the Einstein Telescope and Cosmic Explorer.

Auteur principal

M. Yuhang Zhao (APC, Université Paris Cité)

Documents de présentation