Indisponibilité programmée / Scheduled outage

Nous procéderons à une opération de maintenance le mercredi 12 mars 2025 à 8h00 (CET).

  • Indico sera indisponible durant cette opération.
  • La durée prévisionnelle d'indisponibilité est estimée à une heure.

We will be performing maintenance on Wednesday, March 12, 2025, at 8:00 AM (CET).

  • Indico will be unavailable during this operation.
  • The estimated downtime is one hour.
13–15 juin 2022
Orsay
Fuseau horaire Europe/Paris

Development of a fast Cherenkov detector dedicated to Prompt Gamma Time Imaging

14 juin 2022, 09:25
20m
Amphi Joliot-Curie IJCLab (Orsay)

Amphi Joliot-Curie IJCLab

Orsay

Bat 100A Campus d'Orsay https://www.universite-paris-saclay.fr/luniversite/les-campus/plans-des-campus

Orateur

Maxime Jacquet (LPSC)

Description

We are conceiving a new imaging modality called Prompt Gamma Time Imaging (PGTI) to achieve the real time measurement of the proton range during particle therapy treatments. The goal of PGTI is to reconstruct an image of the vertex distribution of Prompt Gamma rays (PG) emitted from the patient, through the exclusive measurement of particle Time-Of-Flight (TOF). The start trigger is given by a diamond-based beam monitor measuring the proton arrival time, while the stop trigger is provided by a gamma detector. The spatial resolution on the PG vertices strictly depends on the system Coincidence Time Resolution (CTR) between the start and the stop triggers. From MC simulation [Jacquet et al. PMB 2021], we expect a proton range shift sensitivity of 1 mm (at 2 sigma) under the hypothesis of a CTR of 100 ps rms (235 ps FWHM).

In order to achieve these performances within the first (few) second(s) of the treatment, we are developing a dedicated gamma ray detector with a high detection efficiency (~1%) and an excellent time resolution. The TOF Imaging ArRAy (TIARA) will be composed of ~30 1 x 1 x 1 cm3 monolithic PbF2 crystals read out by SiPMs isotropically arranged around the patient.

Two identical block detectors read-out by a dedicated preamplifier and irradiated in coincidence by gamma rays of ~1.25 MeV from a 60Co source achieved a CTR of 278 ps FWHM. The module was also tested with PGs produced at a proton therapy facility using non-dedicated electronics: we obtained a CTR of 317 ps FWHM corresponding to a measured proton range precision of 4 mm (at 2 sigma) with only 600 events. More recently, the use of a new dedicated preamplifier has allowed us to reach a CTR of 235 ps FWHM under the same experimental conditions.

We will present the experimental characterization of our block detector under a proton beam irradiation.

Documents de présentation