Andreas made a detailed presentation on the MC simulation status.
Geometry (with possible minor changes to be discussed offline), timing cut, digitization and flexibility to generate several absorber configurations are already in place.
Vincent made a comment on the timing cut  In fact, it can not be larger than the trigger delay time, which was set to 120 nsec. We may discuss this a little deeper offline or at the meeting. There was also a comment that the sensor has a dead area only at the periphery (guard ring), not inside between the pixels.

Sandhya has shown "pedestal" spectra in 1) BX and 2) BX+1 or +2.
Double peaks are visible in a few channels in 1) but not in 2).
Vladik assumed that delta=50 splitting (too large) in 1) may indicate negative signals, while RMS in 2) (too wide) may indicate there are in fact double but merged peaks in retriggered data.